Hip Abduction Orthosis
Description: Pelvic section attached to adjustable hip joint with thigh cuff
Function: Limit hip range of motion (including hip abduction, flexion/extension); Can be set to limit ROM or to lock in single position
Indication: Hip fractures; Internal fixation; Hip replacement (prosthesis)
Rx: Diagnosis, include ROM settings for hip flexion/extension and hip abduction
Tib/Fib Fx – Sarmiento
Description: Anterior and posterior rigid plastic shells with velcro straps; Foot-ankle insert also attached with velcro to main body of brace; Custom fit to patient
Function: Utlizes hydrostatic compression and external support to maintain stable fracture alignment
Indication: Tibia / Fibula fractures
Rx: Diagnosis